کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166362 1491115 2012 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
چکیده انگلیسی

Multi-way partial least-squares (N-PLS) is combined to the residual bi-linearization procedure (RBL) for the direct analysis of metabolites of polycyclic aromatic hydrocarbons in urine samples. Metabolite analysis is carried out via a two-step experimental procedure based on solid-phase extraction and room temperature fluorescence spectroscopy. Excitation-emission matrices are recorded from octadecyl (C18) membranes that serve as solid substrates for sample extraction and spectroscopic measurements. Excellent metabolite recoveries were obtained in all cases, which varied from 96.2 ± 1.35% (9-hydroxyphenanthrene) to 99.7 ± 0.49% (3-hydroxybenzo[a]pyrene). Background correction of extraction membranes is carried out with a new alternating least-squares (ALS) procedure adapted to second order data. The performance of N-PLS/RBL is compared to the well-established multivariate curve resolution-alternating least-squares (MCR-ALS) algorithm. Both algorithms provided similar analytical figures of merit, including their ability to handle unknown interference in urine samples. With only 10 mL of sample, the limits of detection varied between 0.06–0.08 ng mL−1 (1-hydroxypyrene) and 0.016–0.018 ng mL−1 (2-hydroxyfluorene). When compared to previously reported univariate calibration data, the limits of detection via N-PLS/RBL and MCR-ALS are approximately one order of magnitude higher. This was somehow expected due to the effect of unexpected components in multivariate figures of merit, i.e. a more realistic approach to the analysis of metabolites in human urine samples.

Figure optionsDownload as PowerPoint slideHighlights
► We apply N-PLS/RBL to the analysis of metabolites of polycyclic aromatic hydrocarbons in urine.
► C18 membranes are used for sample extraction and solid substrates for spectroscopic measurements.
► Quantification is made via room-temperature fluorescence excitation emission matrices.
► N-PLS/RBL and RTF-EEM successfully address the issue of spectral overlapping on solid substrates.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 717, 2 March 2012, Pages 100–109
نویسندگان
, , ,