کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166432 1491102 2012 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cytochrome c biosensor for determination of trace levels of cyanide and arsenic compounds
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Cytochrome c biosensor for determination of trace levels of cyanide and arsenic compounds
چکیده انگلیسی

An electrochemical method based on a cytochrome c biosensor was developed, for the detection of selected arsenic and cyanide compounds. Boron doped diamond (BDD) electrode was used as a transducer, onto which cytochrome c was immobilised and used for direct determination of Prussian blue, potassium cyanide and arsenic trioxide. The sensitivity as calculated from cyclic voltammetry (CV) and square wave voltammetry (SWV), for each analyte in phosphate buffer (pH = 7) was found to be in the range of (1.1–4.5) × 10−8 A μM−1 and the detection limits ranged from 4.3 to 9.1 μM. The biosensor is therefore able to measure significantly lower than current Environmental Protection Agency (EPA) and World Health Organisation (WHO) guidelines, for these types of analytes. The protein binding was monitored as a decrease in biosensor peak currents by SWV and as an increase in biosensor charge transfer resistance by electrochemical impedance spectroscopy (EIS). EIS provided evidence that the electrocatalytic advantage of BDD electrode was not lost upon immobilisation of cytochrome c. The interfacial kinetics of the biosensor was modelled as equivalent electrical circuit based on electrochemical impedance spectroscopy data. UV–vis spectroscopy was used to confirm the binding of the protein in solution by monitoring the intensity of the soret bands and the Q bands. FTIR was used to characterise the protein in the immobilised state and to confirm that the protein was not denatured upon binding to the pre-treated bare BDD electrode. SNFTIR of cyt c immobilised at platinum electrode, was used to study the effect of oxidation state on the surface bond vibrations. The spherical morphology of the immobilised protein, which is typical of native cytochrome c, was observed using scanning electron microscopy (SEM) and confirmed the immobilisation of the cytochrome c without denaturisation.

Figure optionsDownload as PowerPoint slideHighlights
► Cytochrome c biosensor for detection of KCN, As2O3 and Fe2K (CN) was constructed.
► Detection limits in the range of 4.3–9.1 μM for the analytes were obtained using CV, SWV and EIS.
► The detection limits for the biosensor were significantly lower than current EPA and WHO guidelines.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 730, 12 June 2012, Pages 49–59
نویسندگان
, , , , ,