کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166621 960505 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of β-sitosterol and cholesterol in oils after reverse micelles with Triton X-100 coupled with ultrasound-assisted back-extraction by a water/chloroform binary system prior to gas chromatography with flame ionization detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of β-sitosterol and cholesterol in oils after reverse micelles with Triton X-100 coupled with ultrasound-assisted back-extraction by a water/chloroform binary system prior to gas chromatography with flame ionization detection
چکیده انگلیسی

Ultrasonic back-extraction of Triton X-100 reverse micelles by a water/chloroform binary system and gas chromatography with flame ionization detection (GC-FID) was developed for extraction and determination of β-sitosterol and cholesterol in soybean and sunflower oil samples. After the homogenization of the oil samples with Triton X-100, an aliquot of 200 μL of methanol was added to the samples to form two phases. The clear Triton X-100 extract obtained by centrifugation was treated with a mixture of water (1000 μL) and chloroform (300 μL) for back-extraction of the analytes into the chloroform phase by ultrasonication. After centrifugation, the sedimented chloroform layer was withdrawn easily by a microsyringe and directly injected into the GC-FID system. The influence of several important parameters on the extraction efficiencies of the analytes was evaluated. Under optimized experimental conditions, the calibration graphs were linear in the range of 1.0–30.0 mg L−1 with coefficient of determination more than 0.994 for both analytes. The method detection limit values were in the range of 0.2–0.7 mg L−1. The lower limit of quantification values were in the range of 0.7–2.4 mg L−1. Intra-day relative standard deviations were in the range of 1.0–2.7%. This procedure was successfully applied with satisfactory results to the determination of β-sitosterol and cholesterol in spiked oil samples. The relative mean recoveries of oil samples ranged from 93.6% to 105.0%.

Figure optionsDownload as PowerPoint slideHighlights
• For the first time reverse micelles with Triton X-100 coupled with ultrasound-assisted backextraction were used for extraction of β-sitosterol and cholesterol.
• This is a direct method for extraction and quantification of cholesterol and β-sitosterol in vegetable oil samples.
• The method is fast and simple as it does not require a previous saponification process.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 701, Issue 2, 9 September 2011, Pages 232–237
نویسندگان
, , ,