کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166947 960519 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High temperature–high efficiency liquid chromatography using sub-2 μm coupled columns for the analysis of selected non-steroidal anti-inflammatory drugs and veterinary antibiotics in environmental samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
High temperature–high efficiency liquid chromatography using sub-2 μm coupled columns for the analysis of selected non-steroidal anti-inflammatory drugs and veterinary antibiotics in environmental samples
چکیده انگلیسی

A high efficiency HPLC method was developed by coupling three sub-2 μm columns in series and operating them at high temperature for the separation of selected non-steroidal anti-inflammatory drugs and veterinary antibiotics in environmental samples. The separation was performed at 80 °C to reduce the solvent viscosity, thus reducing the column backpressure. The chromatographic performance of high temperature-extended column length HPLC method was used to determine the most widely used non-steroidal anti-inflammatory drugs and veterinary antibiotics such as sulphonamides in wastewater samples. The method could simultaneously determine 24 pharmaceuticals in short analysis time with high efficiency. The method involved pre-concentration and clean-up by solid phase extraction (SPE) using Oasis HLB extraction cartridges. It was validated based on linearity, precision, detection and quantification limits, selectivity and accuracy. Good recoveries were obtained for all analytes ranging from 72.7% to 98.2% with standard deviations not higher than 6%, except for acetaminophen and acetyl salicylic acid, for which low recovery was obtained. The detection limits of the studied pharmaceuticals ranged from 2 to 16 μg L−1, while limits of quantification were in the range from 7 to 54 μg L−1 with UV detection.

Figure optionsDownload as PowerPoint slideHighlights
• Three sub-2 μm columns were coupled at high temperature.
• Twenty-four pharmaceuticals could be separated in short analysis time with high efficiency.
• The high efficiency HPLC method was applied to the analysis of real wastewater samples.
• The method was validated based on linearity, precision, detection and quantification limits, selectivity and accuracy.
• Good results were obtained.