کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1170345 960676 2007 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Polymerized Nile Blue derivatives for plasticizer-free fluorescent ion optode microsphere sensors
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Polymerized Nile Blue derivatives for plasticizer-free fluorescent ion optode microsphere sensors
چکیده انگلیسی

Lipophilic H+-selective fluorophores such as Nile Blue derivatives are widely used in ISE-based pH sensors and bulk optodes, and are commonly dissolved in a plasticized matrix such as PVC. Unfortunately, leaching of the active sensing ingredients and plasticizer from the matrix dictates the lifetime of the sensors and hampers their applications in vivo, especially with miniaturized particle based sensors. We find that classical copolymerization of Nile Blue derivatives containing an acrylic side group gives rise to multiple reaction products with different spectral and H+-binding properties, making this approach unsuitable for the development of reliable sensor materials. This limitation was overcome by grafting Nile Blue to a self-plasticized poly(n-butyl acrylate) matrix via an urea or amide linkage between the Nile Blue base structure and the polymer. Optode leaching experiments into methanol confirmed the successful covalent attachment of the two chromoionophores to the polymer matrix. Both polymerized Nile Blue derivatives have satisfactory pH response and appropriate optical properties that are suitable for use in ion-selective electrodes and optodes. Plasticizer-free Na+-selective microsphere sensors using the polymerized chromoionophores were fabricated under mild conditions with an in-house sonic microparticle generator for the measurement of sodium activities at physiological pH. The measuring range for sodium was found as 10−1–10−4 M and 1–10−3 M, for Nile Blue derivatives linked via urea and amide functionalities, respectively, at physiological pH. The observed ion-exchange constants of the plasticizer-free microsphere were log Kexch = −5.6 and log Kexch = −6.5 for the same two systems, respectively. Compared with earlier Na+-selective bulk optodes, the fabricated optical sensing microbeads reported here have agreeable selectivity patterns, reasonably fast response times, and more appropriate measuring ranges for determination of Na+ activity at physiological pH in undiluted blood samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 599, Issue 1, 5 September 2007, Pages 124–133
نویسندگان
, , , , , , ,