Novel preconcentration technique using bis(2-ethylhexyl) hydrogen phosphate (HDEHP) loaded porous polytetrafluoroethylene (PTFE) filter tube as a sorbent: Its application to determination of In(III) in seawater by ICP-MS with air segmented discrete sample
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Novel preconcentration technique using bis(2-ethylhexyl) hydrogen phosphate (HDEHP) loaded porous polytetrafluoroethylene (PTFE) filter tube as a sorbent: Its application to determination of In(III) in seawater by ICP-MS with air segmented discrete sample
چکیده انگلیسی
Novel preconcetration method involving porous polytetrafluoroethylene (PTFE) filter tube impregnated bis(2-ethylhexyl) hydrogen phosphate (HDEHP) as a sorbent was studied to establish it as a practical preconcentration method for ultra trace analysis with ICP-MS. A 1 ng portion of In(III) in 1000 ml of matrix free solution or 700 ml of synthetic seawater was quantitatively complexated with HDEHP adsorbed onto porous PTFE filter tube by passing the solution through the micro pore of the filter tube. Preconcentrated In(III) was then quantitatively recovered provided that the elution, which consists of a cyclical filtering 0.1 ml of 8 mol dm−3 hydrochloric acid through the filter tube for 1 min; therefore, up to 10000- and 7000-fold of enrichment was attained for matrix free solution and synthetic seawater, respectively. To introduce a 0.1 ml of the eluted solution to ICP-MS, flow injection method with air segmented discrete sample introduction (ASDI) was also studied by using manually operated simple valve system. By using ASDI, good linearity of calibration curve (r = 0.99997) was observed from 0.01 to 5.0 ng ml−1 of In(III). Good reproducibility was also shown in measurements of 0.1 ml of 5 ng ml−1 of In(III) (R.S.D. = 1.9%, n = 5). The average recovery and R.S.D. of the results for the five duplicates determination of 0.1 ng of In(III) spiked to 200 ml of synthetic seawater were 99 and 2.4%, respectively. The method was applied to the determination of In(III) in coastal seawater sampled at north east of Hachijyo Island, Japan; using 200 ml of sample, 2000-fold preconcentration of In(III) was performed within 30 min for five samples. The analytical detection limit and the blank were 9.8 and 21 pg l−1, respectively. The average concentration was determined to be 96 pg l−1, and R.S.D. of the results was 3.7% (n = 3).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 556, Issue 2, 25 January 2006, Pages 423-429
نویسندگان
, ,