کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1179803 962798 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Unfolded partial least-squares with residual quadrilinearization: A new multivariate algorithm for processing five-way data achieving the second-order advantage. Application to fourth-order excitation-emission-kinetic-pH fluorescence analytical data
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Unfolded partial least-squares with residual quadrilinearization: A new multivariate algorithm for processing five-way data achieving the second-order advantage. Application to fourth-order excitation-emission-kinetic-pH fluorescence analytical data
چکیده انگلیسی

Unfolded partial least-squares in combination with residual quadrilinearization (U-PLS/RQL), is developed as a new latent structured algorithm for the processing of fourth-order instrumental data. In order to check its analytical predictive ability, fluorescence excitation-emission-kinetic-pH data were measured and processed. The concentration of the fluorescent pesticide carbaryl was determined in the presence of the pesticides fuberidazole and thiabendazole as uncalibrated interferents, in the first example of fourth-order multivariate calibration. The hydrolysis of the analyte was followed at different pH values using a fast-scanning spectrofluorimeter, recording the excitation-emission fluorescence matrices during its evolution to produce 1-naphthol, which does also emit fluorescence. A set of test samples containing the above mentioned fluorescent contaminants was analyzed with the new model, comparing the results with those from parallel factor analysis (PARAFAC). The newly developed U-PLS/RQL model provides better figures of merit for analyte quantitation (average prediction error, 7 μg L−1, relative prediction error, 5%, calibration range, 50–250 μg L−1), and is considerably simpler than PARAFAC in its implementation. The latter, however, furnishes important physicochemical information regarding the chemical process under study, although this requires the data to be unfolded into an array of lower dimensions, due to the lack of quadrilinearity of the experimental data.


► Five-way excitation-emission-reaction time-pH data were measured.
► A new processing algorithm was developed.
► It involves partial least-squares/residual quadrilinearization.
► It provides better results than parallel factor analysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemometrics and Intelligent Laboratory Systems - Volume 109, Issue 2, 15 December 2011, Pages 178–185
نویسندگان
, , ,