کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1182165 1491705 2008 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Gas Chromatography-Mass Spectrometric Determination of Sarin Exposures in Human Serum by Fluoride Reactivation Method
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Gas Chromatography-Mass Spectrometric Determination of Sarin Exposures in Human Serum by Fluoride Reactivation Method
چکیده انگلیسی

The fluoride ion reactivation method was used to determine sarin exposures in human serum using the gas chromatography-mass spectrometry technique. The reaction and extraction conditions were systematically investigated and optimized to regenerate the maximum amount of sarin. The highest reactivation efficiency was 86%, which was calculated from the recovery of butyrylcholinesterase activity. For regenerated sarin over the inhibition of butyrylcholinesterase activity, the linear calibration curve ranged from 6% to 85% and the limit of detection was 4%. No interference of human serum sample was found in this method. It can be used for the retrospective detection of sarin exposures.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chinese Journal of Analytical Chemistry - Volume 36, Issue 9, September 2008, Pages 1269-1272