کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1182313 1491653 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous Determination of 13 Psychiatric Pharmaceuticals in Sewage by Automated Solid Phase Extraction and Liquid Chromatography-Mass Spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous Determination of 13 Psychiatric Pharmaceuticals in Sewage by Automated Solid Phase Extraction and Liquid Chromatography-Mass Spectrometry
چکیده انگلیسی

A method has been developed for the determination of 13 psychiatric pharmaceuticals in wastewater by automated solid phase extraction-high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (ASPE-HPLC-ESI-MS/MS) in positive ion mode and multiple reactions monitoring (MRM). The ASPE extracts were further purified using an amino SPE cartridge prior to HPLC analysis. HPLC separation was performed on an Waters X-bridge C18 column utilizing a gradient elution program of the organic mixture (acetonitrile-methanol, 50:50, V/V) and ammonium formate buffer solution (containing 0.2% formic acid, and adjusted to pH 3.5 with ammonium hydroxide) as the mobile phase. The recoveries of all analytes from matrix spiking experiments in the sewage WWTP's influent and effluent at three concentrations ranged from 93.2% to 106.8%. The matrix effects were 77.3%–98.6% except that for citalopram. Method detection limits for the analytes in the sewage WWTP's influent and effluent were < 1.5 for trihexyphenidyl, carbamazepine and chlorimipramine; 4–12 ng L−1 for alprazolam, fluoxetine, sertraline and fluvoxamine; and 20–80 ng L−1 for lorazepam, clonazepam, oxazepam, zaleplon, paroxetine, respectively. Based on this method, 11 psychiatric pharmaceuticals were detected in 35 wastewater samples from sewage WWTPs except clonazepam and fluvoxamine.

A method was developed for simultaneous determination of 13 psychiatric pharmaceuticals in sewage by automated solid phase extraction-high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry in positive ion mode and multiple reactions monitoring. Based on it, 11 psychiatric pharmaceuticals were detected in 35 sewage samples except clonazepam and fluvoxamine.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chinese Journal of Analytical Chemistry - Volume 41, Issue 1, January 2013, Pages 49–56
نویسندگان
, , , , ,