کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1195250 964302 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Current-Controlled Nanospray Ionization Mass Spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Current-Controlled Nanospray Ionization Mass Spectrometry
چکیده انگلیسی

The hypothesis that direct determination of electrospray current would provide a viable method for maintaining spray stability to enable optimal nanospray analysis was tested by building a feedback apparatus capable of reading the current and readjusting the emitter voltage in real time. The apparatus consists of a current-sensing circuit that reads the voltage drop across a resistor located between the high-voltage power supply and the nanospray emitter. A low voltage proportional to the observed current is generated and sent to a data acquisition card. The information is used by a proportional-derivative-integral (PID) algorithm to calculate the magnitude of a low-voltage signal that is used to control the power supply output. Any variation of current across the sensing resistor is thus counteracted by an opposite-direction variation of the high voltage applied to the nanospray emitter. In this way, the apparatus adjusts the emitter voltage to achieve a preset value of current, which it strives to maintain over time in spite of any possible variation of the parameters influencing the spray regime. Preliminary results have shown that the feedback apparatus is capable of establishing and maintaining stable spray for samples that are usually considered challenging in traditional voltage-controlled analysis, such as those consisting of nucleic acid solutions with high salt loads. For these types of samples, the total ion count recorded in current-controlled mode was significantly more stable than that observed in voltage-controlled mode. At the same time, overall signal intensities and signal-to-noise ratios were also significantly improved. Setting the target nanospray current to a predefined value and letting the apparatus reach the target without operator intervention enabled the acquisition of viable data from solutions containing up to 2.5 M ammonium acetate, which are ordinarily difficult by traditional manual tuning. A deeper understanding of the current–voltage relationships for samples of very different compositions is expected to enable one not only to predict the target current that should be used for a certain analysis, but also to devise algorithms to change such target as a function of predictable variations of sample properties and analytical conditions. This will allow for optimal performance to be maintained during on-line gradient chromatography in which the nature of the sprayed solution may vary very widely during the course of the analysis.

Graphical AbstractA feedback apparatus was designed to perform direct readings of nanospray current and enable real-time adjustments of emitter voltage to improve spray stability.Figure optionsDownload high-quality image (56 K)Download as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American Society for Mass Spectrometry - Volume 20, Issue 7, July 2009, Pages 1334–1341
نویسندگان
, , ,