کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198721 1493470 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Synthesis of mimic molecularly imprinted ordered mesoporous silica adsorbent by thermally reversible semicovalent approach for pipette-tip solid-phase extraction-liquid chromatography fluorescence determination of estradiol in milk
ترجمه فارسی عنوان
سنتز متشکل از مولکولی جذب شده توسط جاذب سیلیسایی مزپوروس به روش سمیووالنت گرمایی برگشت پذیر به منظور بررسی فلوپوریزاسیون کروماتوگرافی مایع کروماتوگرافی استخراج شده در فاز جامد، تعیین استرادیول در شیر
کلمات کلیدی
نشانه گذاری مولکولی تقلبی، سفارش سیلیکا مزوپور، استخراج فاز جامد فیت نیکل، اتراستیل، نمونه های شیر
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Mimic molecularly imprinted ordered mesoporous silica adsorbents are prepared.
• 4,4′-Sulfonyldiphenol and (3-isocyanatopropyl) triethoxysilane used as template and monomer.
• Pipette-tip solid-phase extraction coupled with liquid chromatography detection of estradiol.
• Trace level of estradiol in milk samples were rapidly extracted and isolated.

A mimic molecularly imprinted ordered mesoporous silica (MIOMS) adsorbent was prepared utilizing a thermally reversible semicovalent approach. The thermally reversible covalent template-monomer complex was firstly synthesized by employing 4,4′-sulfonyldiphenol (BPS) and (3-isocyanatopropyl) triethoxysilane (ICPTES) as template and monomer, respectively. The template-monomer complex was incorporated into ordered mesoporous silica via a simple self-assembly process. The adsorption experiment illustrated that the imprint-removed silica (MIOMS-ir) had higher special recognition ability (250 μg g−1) for estradiol (E2) than the non-imprinted silica (NIOMS-ir) (25 μg g−1). MIOMS-ir was applied as an adsorbent in pipette-tip solid-phase extraction (PT-SPE) coupled with liquid chromatography-fluorescence detector (LC-FLD) for determination of E2 in milk samples. Under the optimized conditions, only 3 mg of the adsorbent, 0.3 mL of water as washing solvent, and 0.5 mL of acetonitrile-acetic acid (96:4, v/v) as elution solvent were used in the pretreatment procedure of milk samples. Good calibration linearity was obtained in a range of 25 ng L−1 to 1000 ng L−1, and the recoveries at three spiked levels were ranged from 95.4% to 107.0% with relative standard deviations (RSDs) ≤3.1% (n = 3). The proposed MIOMS-ir-PT-SPE-LC-FLD method combined the advantages of PT-SPE and ordered mesoporous material such as ease assembly, low cost, high extraction efficiency and large specific surface area, so it is a potential pretreatment strategy for the extraction and determination of E2 in complex milk samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1456, 22 July 2016, Pages 58–67
نویسندگان
, , , , ,