کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198746 1493507 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dynamic electromembrane extraction: Automated movement of donor and acceptor phases to improve extraction efficiency
ترجمه فارسی عنوان
استخراج الکترومغناطیسی پویا: حرکت اتوماتیک مراحل اهدا کننده و گیرنده برای بهبود کارایی استخراج
کلمات کلیدی
استخراج الکترومغناطیسی پویا، الیاف توخالی، حرکت خودکار آمیتریپتیلین، نورتریپتیلین
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Dynamic electromembrane extraction was introduced for extraction of ionizable species.
• Organic solvent is impregnated into the pores of hollow fiber as liquid membrane.
• Aqueous acceptor solution is repeatedly pumped into the lumen of hollow fiber.
• A peristaltic pump is used to move sample solution around the mounted hollow fiber.
• Method was applied for extraction of amitriptyline and nortriptyline as model analytes.

In the present research, dynamic electromembrane extraction (DEME) was introduced for the first time for extraction and determination of ionizable species from different biological matrices. The setup proposed for DEME provides an efficient, stable, and reproducible method to increase extraction efficiency. This setup consists of a piece of hollow fiber mounted inside a glass flow cell by means of two plastics connector tubes. In this dynamic system, an organic solvent is impregnated into the pores of hollow fiber as supported liquid membrane (SLM); an aqueous acceptor solution is repeatedly pumped into the lumen of hollow fiber by a syringe pump whereas a peristaltic pump is used to move sample solution around the mounted hollow fiber into the flow cell. Two platinum electrodes connected to a power supply are used during extractions which are located into the lumen of the hollow fiber and glass flow cell, respectively. The method was applied for extraction of amitriptyline (AMI) and nortriptyline (NOR) as model analytes from biological fluids. Effective parameters on DEME of the model analytes were investigated and optimized. Under optimized conditions, the calibration curves were linear in the range of 2.0–100 μg L−1 with coefficient of determination (r2) more than 0.9902 for both of the analytes. The relative standard deviations (RSD %) were less than 8.4% based on four replicate measurements. LODs less than 1.0 μg L−1 were obtained for both AMI and NOR. The preconcentration factors higher than 83-fold were obtained for the extraction of AMI and NOR in various biological samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1419, 6 November 2015, Pages 10–18
نویسندگان
, , , ,