کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198792 1493462 2016 17 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Dealing with the ubiquity of phthalates in the laboratory when determining plasticizers by gas chromatography/mass spectrometry and PARAFAC
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Dealing with the ubiquity of phthalates in the laboratory when determining plasticizers by gas chromatography/mass spectrometry and PARAFAC
چکیده انگلیسی


• The level of ubiquitous DiBP in solvent blanks was assessed using α and β errors.
• PARAFAC succeeds in handling complex finger-peak signals caused by arrays of isomers.
• The determination of DiNP based on PARAFAC loadings instead of areas is more reliable.
• BHT was proved to be present significantly in a dummy intended for infants.

Determining plasticizers and other additives migrated from plastic materials becomes a hard task when these substances are already present in the laboratory environment. This work dealt with this drawback in the multiresidue determination of four plasticizers (2,6-di-tert-butyl-4-methyl-phenol (BHT), diisobutyl phthalate (DiBP), bis(2-ethylhexyl) adipate (DEHA) and diisononyl phthalate (DiNP)) and a UV stabilizer (benzophenone (BP)) by gas chromatography/mass spectrometry (GC/MS) using DiBP-d4 as internal standard. The ubiquity of DiBP by a non-constant leaching process in the laboratory was detected, which could not guarantee the achievement of a trustworthy quantification. To handle this, the assessment of the level of DiBP in solvent blanks having fixed the probabilities of false non-compliance (α) and false compliance (β) at 0.01 was performed. On the other hand, another special case was that of DiNP, in whose chromatogram finger peaks appear because of an array of possible C9 isomers. PARAFAC, used for the identification and quantification of all the substances, is a useful chemometric tool that enabled a more reliable determination of this analyte since no peak areas were considered but chromatographic and spectral loadings.Since phthalates may migrate from rubber latex items, an evaluation of the existence of matrix effects on the determination of the five analytes was conducted prior to an extraction with hexane from a dummy for infants. As matrix effects were present, the quantification of the compounds under study was performed following the standard addition method using PARAFAC sample loadings as response variable. As a result, the presence of BHT was confirmed, being its concentration equal to 37.87 μg L−1. Calibrations based on PARAFAC yielded the following values for the decision limit (CCα): 1.16 μg L−1 for BHT, 1.34 μg L−1 for BP, 1.84 μg L−1 for DEHA and 51.42 μg L−1 for DiNP(for α = 0.05 and two replicates).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1464, 16 September 2016, Pages 124–140