کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1199575 1493554 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
On-line electrodialytic matrix isolation for chromatographic determination of organic acids in wine
ترجمه فارسی عنوان
جداسازی ماتریکس الکترو دیالایتی بر روی خط برای تعیین کروماتوگرافی اسیدهای آلی در شراب
کلمات کلیدی
دستگاه انتقال یونی، پیش آزمون نمونه اسیدهای ارگانیک، کروماتوگرافی حذف یون، شراب
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Rapid and automated matrix isolation procedure for chromatographic determination of organic acids.
• Chemically modified ion transfer membrane for improved anion transfer properties.
• Effective isolation of weak acids from the sample matrix and transfer to ultrapure water.
• No significant sample pH effect on transfer efficiency.
• Successful application to wines, sake and salad dressing.

Chromatographic determination of organic acids is widely performed, but the matrix often calls for lengthy and elaborate sample preparation prior to actual analysis. Matrix components, e.g., proteins, non-ionics, lipids etc. are typically removed by a combination of centrifugation/filtration and solid phase extraction (SPE) that may include the use of ion-exchange media. Here we report the quantitative electrodialytic transfer of organic acids from complex samples to ultrapure water in seconds using cellulose membranes modified with N,N-dimethylaminoethyl methacrylate, which essentially eliminates the negative ζ-potential of a regenerated cellulose membrane surface. The transfer characteristics of the ion transfer device (ITD) were evaluated with linear carboxylic acids. While the ion transfer efficiencies may be affected by the acid dissociation constants, in most cases it is possible to achieve quantitative transfer under optimized device residence time (solution flow rate) and the applied voltage. In addition, the transfer efficiency was unaffected by the wide natural variation of pH represented in real samples. The approach was applied to organic acids in various samples, including red wine, considered to represent an especially difficult matrix. While quantitative transfer of the organic acids (as judged by agreement with standard pretreatment procedures involving SPE) was achieved, transfer of other matrix components was <5%. The processed samples could then be chromatographically analyzed in a straightforward manner. We used ion exclusion chromatography with direct UV detection; in treated samples; there was a dramatic reduction of the large early peaks observed compared to only 0.45 μm membrane filtered samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1372, 12 December 2014, Pages 18–24
نویسندگان
, , , , , , ,