Using a postcolumn-infused internal standard for correcting the matrix effects of urine specimens in liquid chromatography–electrospray ionization mass spectrometry
ترجمه فارسی عنوان
با استفاده از یک استاندارد داخلی پس از تزریق، برای اصلاح اثرات ماتریس نمونه های ادرار در کروماتوگرافی مایع، اسپکترومتری جرم یونیزاسیون الکترو اسپری
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• An effective and economic PCI-IS method for MEs correction in LC–ESI-MS.
• PCI-IS could effectively correct MEs in urine specimens.
• PCI-IS method resolved the drawbacks of traditional internal standard method.

Matrix effects (MEs) are a major problem affecting the quantitative accuracy of liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) when analyzing complicated samples. While analyzing urine specimens, the wide diversity of endogenous materials and different urine concentrations may result in inaccurate quantification. In this study, we propose a postcolumn-infused internal standard (PCI-IS) strategy for universal correction of MEs in urine specimens. MEs can be effectively corrected by dividing the target analyte signal intensity by the PCI-IS intensity. To evaluate the performance of PCI-IS, we used 6 benzodiazepine (BZD) drugs in 5 different concentrations of urine matrixes as a test model. The divergence of the BZD drug signal responses in 5 different urine matrixes was expressed using their respective coefficients of variation (CV) to evaluate the efficiency of using PCI-IS in correcting matrix effects. The CV of the BZD drug signal intensities in these 5 different concentrations of the urine matrixes were reduced from 10 to 30% to less than 10% when the PCI-IS correction method was employed. When the PCI-IS method was used to correct the 6 BZDs in 25 real human urine samples, over 90% of the test results exhibited quantification errors of less than 20%, and all of the test results had quantification errors of less than 30%. These results demonstrate that the PCI-IS method can resolve the problem of inaccurate quantification that arises from the diversity of urine specimens. The PCI-IS method is particularly useful for clinical analysis or forensic toxicology to improve the quantification accuracy in an economical way.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1327, 31 January 2014, Pages 97–104
نویسندگان
, , , ,