کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1199751 1493561 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous and high-throughput analysis of iodo-trihalomethanes, haloacetonitriles, and halonitromethanes in drinking water using solid-phase microextraction/gas chromatography-mass spectrometry: an optimization of sample preparation
ترجمه فارسی عنوان
تجزیه و تحلیل همزمان و با توان بالا از یدتهیوالومتنها، هالوآکستونیتریلها و هالونیترومتانها در آب آشامیدنی با استفاده از میکروسکتراسیون جامد / طیف سنجی جرمی کروماتوگرافی گاز: بهینه سازی آماده سازی نمونه
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A rapid SPME–GC/MS method was developed for analysis of 20 emerging volatile DBPs.
• The method is rapid, sensitive, and precise for iodinated and nitrogenous analyses.
• The LODs for Iodo-THMs, HANs, and HNMs compounds ranged from 1 to 50 ng/L.
• The method is suitable for drinking water analysis with negligible matrix effects.
• A survey of drinking water showed most target analytes were lower than μg/L levels.

When iodide and natural organic matter are present in raw water, the formation of iodo-trihalomethanes (Iodo-THMs), haloacetonitriles (HANs), and halonitromethanes (HNMs) pose a potential health risk because they have been reported to be more toxic than their brominated or chlorinated analogs. In the work, simultaneous analysis of Iodo-THMs, HANs, and HNMs in drinking water samples in a single cleanup and chromatographic analysis was proposed. The DVB/CAR/PDMS fiber was found to be the most suitable for all target compounds, although 75 μm CAR/PDMS was better for chlorinated HANs and 65 μm PDMS/DVB for brominated HNMs. After optimization of the SPME parameters (DVB/CAR/PDMS fiber, extraction time of 30 min at 40 °C, addition of 40% w/v of salt, (NH4)2SO4 as a quenching agent, and desorption time of 3 min at 170 °C), detection limits ranged from 1 to 50 ng/L for different analogs, with a linear range of at least two orders of magnitude. Good recoveries (78.6–104.7%) were obtained for spiked samples of a wide range of treated drinking waters, demonstrating that the method is applicable for analysis of real drinking water samples. Matrix effects were negligible for the treated water samples with total organic carbon concentration of less than 2.9 mg/L. An effective survey conducted by two drinking water treatment plants showed the highest proportion of Iodo-THMs, HANs, and HNMs occurred in treated water, and concentrations of 13 detected compounds ranged between the ng/L and the μg/L levels.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1365, 24 October 2014, Pages 45–53
نویسندگان
, , , , , ,