کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200125 1493593 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
On-line headspace-multicapillary column-ion mobility spectrometry hyphenation as a tool for the determination of off-flavours in foods
ترجمه فارسی عنوان
برش خط اسپکترومتری تحرک یونی ستونهای سرپوش چندگانه ای به صورت یک ابزار برای تعیین خنثی کردن طعم در غذاها
کلمات کلیدی
اکسیداسیون لیپید، اسیدهای چرب غیر اشباع امگا 3 زنجیره طولانی، طیف سنجی حرکت یون، شیر، روغن بزرک، خنثی کردن
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• The coupling HS–MCC–IMS has been evaluated to monitor lipid oxidation products.
• Milk with different flavours and linseed oil samples has been analysed.
• The volatile profile was studied during 36 days under different storage conditions.
• Hexanal, 2-butanone, acetone and dimethyl sulfide were main degradation products.

In this work, an ion mobility spectrometer (IMS) with a tritium ionization source on-line coupled to a headspace (HS) autosampler and a multicapillary column (MCC) was evaluated for the monitoring of lipid oxidation products in milk with different flavours (cacao, fruits, cereals and nuts) and linseed oil samples enriched with omega-3 acids. In this combination, the multicapillary column is used as an interface between the HS and the IMS, providing the efficient separation of the volatile compounds. In this way, the proposed method permits the detection of hexanal, 2-butanone, acetone and dimethyl sulfide as representative degradation products. The limits of detection were in the interval 0.3 μg L−1 (for hexanal in milk) to 3.0 μg L−1 (for dimethyl sulfide in linseed oil) while the limits of quantification varied between 1.1 μg L−1 (for hexanal in milk) and 9.6 μg L−1 (for dimethyl sulfide in linseed oil). The precision of the method was evaluated as relative standard deviation and the values were better than 8% in all cases. The evolution of the volatiles profile during 36 days under different storage conditions (temperature, oxygen and light) demonstrates the capability of the HS–MCC–IMS coupling for the estimation of the degradation of the samples. After the degradation study, it can be concluded that the stability of the milk samples during storage is more affected by the light while temperature was more critical for oil samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1333, 14 March 2014, Pages 99–105
نویسندگان
, , , ,