کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200355 1493481 2016 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Identification of flurochloridone metabolites in rat urine using liquid chromatography/high resolution mass spectrometry
ترجمه فارسی عنوان
شناسایی متابولیتهای فلورکلریدون در ادرار موش با استفاده از کروماتوگرافی مایع / اسپکترومتری جرمی با وضوح بالا
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• AMBIPR was used for screening metabolites with naturally distinct isotopic pattern.
• Library identification was established via Mass Frontier with satisfactory performance.
• FLC metabolites (totally 97) were screened with low false positive and negative.
• Metabolites with indistinct isotopic pattern were also successfully screened.
• Much more efficiency and selectivity were observed in AMBIPR than in BS + MDF.

It is of great interest to develop strategic methods to enable chemicals’ metabolites to be accurately and rapidly screened and identified. To screen and identify a category of metabolites with distinct isotopic distribution, this study proposed a generic strategy using in silico metabolite prediction plus accurate-mass-based isotopic pattern recognition (AMBIPR) and library identification on the data acquired via the data dependent MS/MS scan of LC-Q Exactive Orbitrap mass spectrometry. The proposed method was evaluated by the analysis of flurochloridone (FLC) metabolites in rat urine sample collected from toxicity tests. Different from the traditional isotopic pattern recognition (IPR) approach, AMBIPR here was performed based on the potential metabolites predicted via in silico metabolite prediction tools. Thus, the AMBIPR treated FLC data was only associated with FLC metabolites, consequently not only avoiding great efforts made to remove FLC-unrelated information and reveal FLC metabolites, but also increasing the percent of positive hits. Among the FLC metabolite peaks screened using AMBIPR, 87% of them (corresponding 97 metabolites and 49 biotransformation) were successfully identified via multiple MS identification techniques packaged in an established FLC’s metabolites library based on Mass Frontier. Noteworthy, 34 metabolites (89%) were identified without distinct naturally isotopic distribution. The universal strategic approach based on background subtraction (BS) and mass defect filtering (MDF) was used to evaluate the AMBIPR and no more false positive and negative metabolites were detected. Furthermore, our results revealed that AMBIPR is very effective, inherently sensitive and accurate, and is easily automated for the rapidly screening and profiling chemicals related metabolites.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1445, 6 May 2016, Pages 80–92
نویسندگان
, , , , , , , , , , , , ,