چکیده انگلیسی


• A novel sorbent for urinary monitoring of NSAIDs is synthesized.
• This novel sorbent is poly(2-aminobenzothiazole)-coated magnetic graphen oxide.
• The sorbent benefits from the excellent properties of GO, polymer and Fe3O4.
• Poly(2-aminobenzothiazole) enhanced the extraction efficiency of GO/Fe3O4.
• Small amounts of sorbent and organic solvent were required.

In this study, for the first time, 2-aminobenzothiazole monomer was polymerized on Fe3O4 NPs, graphene oxide/Fe3O4 (GO/Fe3O4) and graphene/Fe3O4 (G/Fe3O4) nanocomposites. The synthesized magnetic nanosorbents were characterized by various techniques. The extraction ability of these nanosorbents including Fe3O4, GO/Fe3O4, G/Fe3O4, Fe3O4@poly(2-aminobenzothiazole) (Fe3O4@PABT), GO/Fe3O4@PABT and G/Fe3O4@PABT were compared for dispersive-micro-solid phase extraction of three non-steroidal anti-inflammatory drugs. The results revealed that GO/Fe3O4@PABT nanocomposite demonstrates higher extraction efficiency for naproxen, diclofenac and ibuprofen as selected model analytes. Following the sorption and elution steps, the model analytes were quantified by high performance liquid chromatography-photo diode array detection. Afterwards, a central composite design methodology combined with desirability function approach was applied to find out the optimal experimental conditions. Under the optimized conditions, the limits of detection and linear dynamic ranges were achieved in the range of 0.07-0.3 μg L−1 and 0.25–2000 μg L−1, respectively. The percent of extraction recovery was 87.4, 85.5 and 90.5% for naproxen, diclofenac and ibuprofen, respectively. The obtained relative standard deviation (n = 5) was 7.2, 5.4 and 6.4% for naproxen, diclofenac and ibuprofen, respectively. Ultimately, this method was employed for urinary monitoring of the target analytes and satisfactory results were obtained.