کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200570 1493622 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of chip-based photocatalyst-assisted reduction device to couple high performance liquid chromatography and inductively coupled plasma-mass spectrometry for determination of inorganic selenium species
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development of chip-based photocatalyst-assisted reduction device to couple high performance liquid chromatography and inductively coupled plasma-mass spectrometry for determination of inorganic selenium species
چکیده انگلیسی


• The PMMA chip was first developed for online vaporization of inorganic Se species.
• Analytical signals were significantly enhanced by using our developed system.
• The most exciting of the proposed system is its high performance with low cost.

In this study, a poly(methyl methacrylate) chip-based photocatalyst-assisted reduction device (PMMA chip-based PCARD) was developed as a reactor based on its excellent optical properties and ease of fabrication. Its transmittance of ultraviolet light at 365 nm (UV365) was found to be as high as 92% using a PMMA of 2 mm thickness. To optimize the vaporization efficiency, the effect of varying the depth of the geometry trenched on the PMMA-based chip was investigated. After optimization, it required only 29 s of UV365 irradiation to vaporize the selenium (Se) species of interest. The PMMA-based chip was successfully used as an interfacing device for the hyphenation of high performance liquid chromatography (HPLC) separation and inductively coupled plasma-mass spectrometry (ICP-MS) detection. Additionally, under the optimized conditions for vaporization, using 1 g L−1 titanium dioxide nanoparticles (nano-TiO2) at pH 5, we found that Se(IV) and Se(VI) were converted quantitatively into volatile Se products. In addition, the optimized vaporization efficiency of the Se species of interest for the online HPLC/PMMA chip-based PCARD/ICP-MS system enabled us to achieve detection limits for Se(IV) and Se(VI) in the nanogram-per-liter range (based on 3σ). A series of validation experiments indicated that our proposed methods could be applied satisfactorily to the determination of inorganic Se species in environmental water samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1304, 23 August 2013, Pages 101–108
نویسندگان
, , , , ,