کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1200597 1493676 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of ultraviolet filters in water samples by vortex-assisted dispersive liquid–liquid microextraction followed by gas chromatography–mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of ultraviolet filters in water samples by vortex-assisted dispersive liquid–liquid microextraction followed by gas chromatography–mass spectrometry
چکیده انگلیسی

For the first time, a simple solvent microextraction method termed vortex-assisted liquid–liquid microextraction (VADLLME) coupled with gas chromatography–mass spectrometry (GC–MS) has been developed and used for the analysis of six benzophenone ultraviolet (UV) filters (i.e. benzhydrol, 2,4-dihydroxybenzophenone, benzophenone, 2-hydroxy-4-methoxybenzophenone, ethylhexyl salicylate and homosalate) in water samples. The most favorable extraction variables in the VADLLME process were determined. In the extraction procedure, 40 μL of tetrachloroethene as extraction solvent were directly injected into a 15-mL centrifuge tube containing 10 mL of aqueous sample, adjusted to pH 4 for VADLLME. After VADLLME, the extract was evaporated under a gentle nitrogen gas stream and then reconstituted with N,O-bis-(trimethylsilyl)trifluoroacetamide (BSTFA), thus allowing the target analytes to be converted into their trimethylsilyl derivatives to optimize the GC–MS analysis. No centrifugation and disperser solvent were required in this microextraction procedure. Significantly, short extraction time and high extraction efficiency were achieved. This method opens up a potentially new horizon for on-site dispersive liquid–liquid microextraction. Under the optimum conditions, the proposed method provided good enrichment factors up to 310, with relative standard deviations ranging from 6.1 to 12.9%. The limits of quantification were in the range of 20–100 ng/L, depending on the analytes. The linearities were between 0.05 and 10 μg/L and 0.1 and 10 μg/L for different UV filters. Finally, the proposed method was successfully applied to the determination of UV filters from spiked genuine water samples and acceptable recoveries over the range of 71.0–120.0% were obtained.


► VADLLME-GC–MS was for the first time applied to the determination of UV filters.
► High extraction efficiency with good enrichment factors up to 310 were achieved.
► The new method did not need centrifugation or disperser solvent.
► Fast extraction time relative to other methods was another advantage.
► Simple and efficient method with low LODs, good repeatability and linearity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1249, 3 August 2012, Pages 25–31
نویسندگان
, ,