کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1201387 1493628 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An high-performance liquid chromatographic method for the simultaneous analysis of acetylcarnitine taurinate, carnosine, asparagine and potassium aspartate and for the analysis of phosphoserine in alimentary supplements
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
An high-performance liquid chromatographic method for the simultaneous analysis of acetylcarnitine taurinate, carnosine, asparagine and potassium aspartate and for the analysis of phosphoserine in alimentary supplements
چکیده انگلیسی


• Simultaneous analysis of AC-Tau, Carn, Asn and Asp is reported for the first time.
• Derivatization studies in placebo excluded any interference of complex matrices.
• The high stability of the adducts allowed automated analyses at company level.
• The amino acid analysis was carried out without preliminary extraction procedures.

A RP-HPLC method with pre-column derivatization was developed and validated for the simultaneous quantification of carnosine (Carn), acetylcarnitine taurinate (AC-Tau), asparagine (Asn), potassium aspartate (Asp) and for the determination of phosphoserine (p-Ser) in new and commercial alimentary supplements. The effect of complex matrices was evaluated by the study of the amino acid derivatization reaction with 2,4-dinitrofluorobenzene (DNFB) both in standard and placebo solutions. The reaction was carried out for 20 min at 70 ̊C in alkaline medium (pH10) for p-Ser analysis, whereas for 60 min in the case of Carn, AC-Tau, Asn and Asp analysis. The adducts have been separated on a Discovery RP Amide C16 (250 mm × 4.6 mm, i.d.) column using a mobile phase consisting of acetonitrile (ACN) and triethylammonium (TEA) phosphate buffer (pH 3, 0.05 M) under gradient elution conditions at a flow-rate of 0.8 mL/min. Detection was set at λ = 360 nm. The validation parameters such as linearity, sensitivity, accuracy, precision and specificity were found to be highly satisfactory. Linear responses were observed by placebo solutions (determination coefficient ≤0.9996). Intra-day precision (relative standard deviation, RSD) was ≤1.06% for corrected peak area and ≤0.99% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all examined compounds (from 97.7% to 101.5%) with RSD ranging from 0.5% to 1.3%). The high stability of derivatized compound solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of a large number of samples and consecutive chromatographic analyses by the use of an autosampler. The developed method can be considered suitable for the quality control of new and commercial products.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1298, 12 July 2013, Pages 95–102
نویسندگان
, , ,