کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1202852 1493698 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultra high performance liquid chromatography–atmospheric pressure photoionization-mass spectrometry for high-sensitivity analysis of US Environmental Protection Agency sixteen priority pollutant polynuclear aromatic hydrocarbons in oysters
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Ultra high performance liquid chromatography–atmospheric pressure photoionization-mass spectrometry for high-sensitivity analysis of US Environmental Protection Agency sixteen priority pollutant polynuclear aromatic hydrocarbons in oysters
چکیده انگلیسی

In response to Gulf of Mexico deepwater horizon oil spill, we have developed an atmospheric pressure photoionization (APPI) based ultra high performance liquid chromatography–mass spectrometry (UHPLC–MS) method for high-sensitivity analysis of United States Environmental Protection Agency (US EPA) 16 priority pollutant polynuclear aromatic hydrocarbons (PAHs) in oysters. Analyses were performed on an Agilent's Infinity 1290 UHPLC system coupled with a G6140A single quadrupole MS detector with Syagen's PhotoMate® APPI® source. Column separation was achieved using Zorbax Eclipse PAH column. Chlorobenzene was used as an APPI dopant for maximum overall sensitivity. Dynamic linear ranges were evaluated and found to cover 3.6–5.1 (Ave. 4.4) orders of magnitude with R2 of at least 0.995. A quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and cleanup procedure was used. The spike recoveries ranged from 77% to 110% with %RSD of 0.6–6.7 at spike concentrations below or substantially below the US Food and Drug Administration (FDA) level of concern in oysters. The on-column instrument detection limits (IDLs, 6σ S/N = 3) ranged from 8 to 106 pg with an average of 23 pg for 16 PAHs. The method detection limits (MDLs, 6σ S/N = 3) ranged from 0.013 to 0.129 ppm with an average of 0.040 ppm for all analytes. These MDLs were about 5 times to over 4 orders of magnitude lower than US FDA levels of concern in oysters.


► APPI based UHPLC–MS method was developed for analysis of US EPA 16 PAHs in oysters.
► Linear ranges covered 3.6–5.1 (Ave. 4.4) orders of magnitude with R2 of at least 0.995.
► Spike recoveries were 77–110% at conc. below or much below US FDA level of concern.
► MDLs (6σ S/N = 3) ranged from 0.013 to 0.129 ppm (Ave. 0.040 ppm) for all analytes.
► MDLs were ∼5 times to over 4 orders of magnitude lower than US FDA levels of concern.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1227, 2 March 2012, Pages 138–144
نویسندگان
, , ,