کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1206835 | 1493719 | 2008 | 7 صفحه PDF | دانلود رایگان |

The purification of human immunoglobulin G (IgG) from a Chinese hamster ovary (CHO) cells supernatant was studied using an aqueous two-phase system (ATPS) composed of ethylene oxide/propylene oxide (UCON) and dextran. In UCON/dextran systems IgG partitions preferentially to the less hydrophobic dextran-rich phase (Kp < 1). The addition of triethylene glycol-diglutaric acid (TEG-COOH) shifted the IgG partition into the upper phase showing significant improvements in both the recovery yields and purity. The purification of IgG from a CHO cell supernatant with UCON 2000/dextran/TEG-COOH system was optimised using a central composite design. Using an ATPS composed of 8% UCON, 6% dextran and 20% TEG-COOH, IgG was purified, in two steps, with a global yield of 85% and 88% purity. Statistical valid models were obtained to predict the effect of the experimental conditions on the IgG yield and purity, for both extraction and back-extraction steps. A system composed of 10% UCON, 5.5% dextran and 20% TEG-COOH was identified as the best compromise between final purity and yield.
Journal: Journal of Chromatography A - Volume 1195, Issues 1–2, 27 June 2008, Pages 94–100