کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1210827 | 965421 | 2008 | 6 صفحه PDF | دانلود رایگان |
We examined the performance of the Chemcatcher (University Portsmouth, UK) in two different configurations when used for the aquatic passive sampling of a 1-day pulse contamination with thiacloprid under field-relevant conditions. The configuration without diffusion-limiting membrane led to biofouling of the Empore disk receiving phase resulting in a fourfold reduction in analyte uptake compared to unfouled passive samplers. The sampling rate for the configuration with diffusion-limiting polyethersulfone membrane was also much lower than in a long-term exposure scenario, although no biofouling occurred. Both configurations of the Chemcatcher exhibited high variation in analyte uptake with up to 100% RSD. Short-term contamination events may be underestimated in passive sampling when the receiving phase is biofouled or a diffusion-limiting membrane is employed.
Journal: Journal of Chromatography A - Volume 1203, Issue 1, 29 August 2008, Pages 1–6