کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1213187 1494141 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Rapid detection of sepsis in rats through volatile organic compounds in breath
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Rapid detection of sepsis in rats through volatile organic compounds in breath
چکیده انگلیسی

BackgroundSepsis is one of the main causes of death in adult intensive care units. The major drawbacks of the different methods used for its diagnosis and monitoring are their inability to provide fast responses and unsuitability for bedside use. In this study, performed using a rat sepsis model, we evaluate breath analysis with Ion Mobility Spectrometry (IMS) as a fast, portable and non-invasive strategy.MethodsThis study was carried out on 20 Sprague-Dawley rats. Ten rats were injected with lipopolysaccharide from Escherichia coli and ten rats were IP injected with regular saline. After a 24-h period, the rats were anaesthetized and their exhaled breaths were collected and measured with IMS and SPME-gas chromatography/mass spectrometry (SPME-GC/MS) and the data were analyzed with multivariate data processing techniques.ResultsThe SPME-GC/MS dataset processing showed 92% accuracy in the discrimination between the two groups, with a confidence interval of between 90.9% and 92.9%. Percentages for sensitivity and specificity were 98% (97.5–98.5%) and 85% (84.6–87.6%), respectively. The IMS database processing generated an accuracy of 99.8% (99.7–99.9%), a specificity of 99.6% (99.5–99.7%) and a sensitivity of 99.9% (99.8–100%).ConclusionsIMS involving fast analysis times, minimum sample handling and portable instrumentation can be an alternative for continuous bedside monitoring. IMS spectra require data processing with proper statistical models for the technique to be used as an alternative to other methods. These animal model results suggest that exhaled breath can be used as a point-of-care tool for the diagnosis and monitoring of sepsis.


► Breath analysis with Ion Mobility Spectrometry (IMS) was used as rapid diagnosis for sepsis.
► High levels of accuracy, specificity and sensitivity were achieved by processing IMS spectra.
► Breath samples were measured with GC/MS as reference technique.
► A pattern of compounds were related to sepsis by analysing chromatograms of GC/MS.
► Results showed that breath analysis can be used as point of care tool for diagnosis of sepsis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volumes 881–882, 15 January 2012, Pages 76–82
نویسندگان
, , , , , , , ,