کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1213401 1494128 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Metaxalone estimation in biological matrix using high-throughput LC–MS/MS bioanalytical method
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Metaxalone estimation in biological matrix using high-throughput LC–MS/MS bioanalytical method
چکیده انگلیسی

Metaxalone is a skeletal muscle relaxant, an approved drug for pain relief. Published bioanalytical methods lacked detailed stability evaluation in blood and plasma. An accurate, precise, high-throughput tandem mass spectroscopic method has been developed and validated. Following solid phase extraction (SPE), metaxalone and the internal standard metaxalone-d3 were extracted from an aliquot of 200 μL of human plasma. Chromatographic separation achieved on an Ascentis Express C18 column (50 mm × 4.6 mm i.d., 2.7 μm particle size) with mobile phase is a mixture of 10 mM ammonium acetate buffer (pH 4.5)–methanol–acetonitrile (20:50:30, v/v/v), at an isocratic flow rate of 0.7 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. The mass transitions of metaxalone and metaxalone-d3 were m/z 222.3 → 161.2 and m/z 225.3 → 163.3, respectively. The linear calibration curves were obtained in the concentration range of 0.105–10.081 μg/mL (r2 ≥ 0.99) with a lower limit of quantification (LLOQ) of 0.105 μg/mL. The intra- and inter-day precisions and relative error were all within 6%. Despite achieving high mean recovery (>78%), no interference peaks or matrix effects were observed. Detailed stability exercises including drug stability in blood, hemolyzed, lipemic and normal plasma were conducted to extend the method applicability in vast majority of clinical studies using 800 mg metaxalone extended release oral dosage form.


► High-throughput bioanalytical method was developed and validated adhering to global regulatory norms.
► We examined metaxalone in blood, plasma and in hemolyzed/lipemic plasma for effect of matrix component interference.
► Achieved mean recovery >78% for both metaxalone and its internal standard and intra- and inter-day precisions and accuracy were all within 6%.
► We have found that matrix effect was negligible though the method is sensitive and demonstrated high extraction efficiency.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 902, 1 August 2012, Pages 132–136
نویسندگان
, , , , , ,