کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1215107 1494152 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simple and selective method for the determination of various tyrosine kinase inhibitors used in the clinical setting by liquid chromatography tandem mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simple and selective method for the determination of various tyrosine kinase inhibitors used in the clinical setting by liquid chromatography tandem mass spectrometry
چکیده انگلیسی

A fast, sensitive, universal and accurate method for the determination of four different tyrosine kinase inhibitors from biological material was developed using LC–MS/MS techniques. Utilizing a simple protein precipitation with acetonitrile a 20 μl sample volume of biological matrixes can be extracted at 4 °C with minimal effort. After centrifugation the sample extract is introduced directly onto the LC–MS/MS system without further clean-up and assayed across a linear range of 1–4000 ng/ml. Chromatography was performed using a Dionex Ultimate 3000 with a Phenomenex prodigy ODS3 (2.0 mm × 100 mm, 3 μm) column and eluted at 200 μl/min with a tertiary mobile phase consisting of 20 mM ammonium acetate:acetonitrile:methanol (2.5:6.7:8.3%). Injection volume varied from 0.1 μl to 1 μl depending on the concentration of the drug observed. Samples were observed to be stable for a maximum of 48 h after extraction when kept at 4 °C. Detection was performed using a turbo-spray ionization source and mass spectrometric positive multi-reaction-monitoring-mode (+MRM) for Gefitinib (447.1 m/z; 127.9 m/z), Erlotinib (393.9 m/z; 278.2 m/z), Sunitinib (399.1 m/z; 283.1 m/z) and Sorafenib (465.0 m/z; 251.9 m/z) at an ion voltage of +3500 V. The accuracy, precision and limit-of-quantification (LOQ) from cell culture medium were as follows: Gefitinib: 100.2 ± 3.8%, 11.2 nM; Erlotinib: 101.6 ± 3.7%, 12.7 nM; Sunitinib: 100.8 ± 4.3%, 12.6 nM; Sorafenib: 93.9 ± 3.0%, 10.8 nM, respectively. This was reproducible for plasma, whole blood, and serum. The method was observed to be linear between the LOQ and 4000 ng/ml for each analyte. Effectiveness of the method is illustrated with the analysis of samples from a cellular accumulation investigation and from determination of steady state concentrations in clinically treated patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 878, Issues 15–16, 1 May 2010, Pages 1059–1068
نویسندگان
, , , , , , , , , ,