Quantitative analysis of the opioid peptide DAMGO in rat plasma and microdialysis samples using liquid chromatography–tandem mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Quantitative analysis of the opioid peptide DAMGO in rat plasma and microdialysis samples using liquid chromatography–tandem mass spectrometry
چکیده انگلیسی

A liquid chromatography–electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) method for the quantification of the opioid peptide DAMGO in rat plasma, as well as DAMGO and the microdialysis recovery calibrator [13C2,15N]-DAMGO in microdialysis samples, is described. The microdialysis samples consisted of 15 μL Ringer solution containing 0.5% bovine serum albumin. Pretreatment of the samples involved protein precipitation with acetonitrile followed by dilution with 0.01% formic acid. The lower limits of quantification were 0.52 ng/mL and 0.24 ng/mL for DAMGO and [13C2,15N]-DAMGO respectively and the response was linear up to 5000 fold higher concentrations. The plasma samples (50 μL) were precipitated with acetonitrile containing the isotope labeled analog [13C2,15N]-DAMGO as internal standard. The method was linear in the range of 11–110,000 ng/mL. The separations were conducted on a HyPurity C18 column, 50 × 4.6 mm, 3 μm particle size, with a mobile phase consisting of acetonitrile, water and formic acid to the proportions of 17.5:82.5:0.01. Low energy collision dissociation tandem mass spectrometric (CID-MS/MS) analysis was carried out in the positive ion mode using multiple reaction monitoring (MRM) of the following mass transitions: m/z 514.2 → 453.2 for DAMGO and m/z 517.2 → 456.2 for [13C2,15N]-DAMGO. The intra-day precision and accuracy did not exceed 5.2% and 93–104% for both compounds and sample types described. The inter-day precision an accuracy were <6.8% and 95–105% respectively. The method described is simple, reproducible and suitable for the analysis of small sample volumes at low concentrations.


► Analysis of DAMGO in microdialysis samples and plasma using LC–MS/MS is described.
► Plasma method was linear between 11 and 110,000 ng/mL. Sample volume was 50 μL.
► Microdialysis method was linear between 0.52 and 2600 ng/mL. Sample volume was 15 μL.
► The intra-day and inter-day precision and accuracy did not exceed 6.8% and 93–105%.
► The method was applied to determine the brain distribution of DAMGO in rat.