کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1217465 | 1494193 | 2006 | 4 صفحه PDF | دانلود رایگان |

A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of p-coumaric acid in rat plasma and applied to a pharmacokinetic study in rats after administration of a prodrug, E-6-O-p-coumaroyl scandoside methyl ester, isolated from Hedyotis diffusa (Willd.). Sample preparation involved protein precipitation with acetonitrile. The supernatant was then injected onto a DiamonsilTM C18 column (250 mm × 4.6 mm i.d., 5 μm). The mobile phase consisted of acetonitrile–water (21:79, v/v) with 1% glacial acetic acid. The UV detector was set at 310 nm. The lower limit of quantification of p-coumaric acid in rat plasma was 0.02 μg/mL. The calibration curves were linear over the concentration range 0.02–5 μg/mL with correlations greater than 0.999. The assay procedure was applied to the study of the metabolite pharmacokinetics of E-6-O-p-coumaroyl scandoside methyl ester in rat.
Journal: Journal of Chromatography B - Volume 831, Issues 1–2, 2 February 2006, Pages 303–306