کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1217825 1494179 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quantitative HPLC-UV method for the determination of firocoxib from horse and dog plasma
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Quantitative HPLC-UV method for the determination of firocoxib from horse and dog plasma
چکیده انگلیسی

A sensitive reversed-phase HPLC-UV method was developed for the determination of firocoxib, a novel and highly selective COX-2 inhibitor, in plasma. A 1.0 mL dog or horse plasma sample is mixed with water and passed through a hydrophobic–lipophilic copolymer solid-phase extraction column to isolate firocoxib. Quantitation is based on an external standard curve. The method has a validated limit of quantitation of 25 ng/mL and a limit of detection of 10 ng/mL. The validated upper limit of quantitation was 2500 ng/mL for horses and 10,000 ng/mL for dogs. The average recoveries ranged from 88–93% for horse plasma and 96–103% for dog plasma. The coefficient of variation in all cases was less than 10%. This method is suitable for the analysis of clinical samples from pharmacokinetic and bioequivalence studies and drug monitoring.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 854, Issues 1–2, 1 July 2007, Pages 313–319
نویسندگان
, , , ,