کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1221479 1494646 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An eco-friendly strategy, using on-line monitoring and dilution coupled to a second-order chemometric method, for the construction of dissolution curves of combined pharmaceutical associations
ترجمه فارسی عنوان
یک استراتژی سازگار با محیط زیست، با استفاده از نظارت بر روی خط و رقیق همراه با روش شیمیایی مرتبه دوم، برای ساخت منحنی انحلال انجمن های ترکیبی دارویی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• On-line dilution overcomes lack of linearity and detector saturation problems.
• OD/UV-MCR complies with green analytical chemistry principles and strategies.
• The simultaneous dissolution curves of CAR and HCT were monitored.
• The method is more efficient than HPLC; requires minimum operator intervention.
• Multipoint dissolution profiles are more suitable for evaluation of similarity.

A simple, precise, economic and minimally operator-dependent method was developed under green analytical chemistry principles, for the simultaneous construction of the dissolution curves of a pharmaceutical association in short time and without employing organic solvents, allowing important savings of labor and resources. The carvedilol (CAR) and hydrochlorothiazide (HCT) combined formulation was employed as a model. The method (OD/UV-MCR) involves on-line sample dilution (OD) and UV detection of the analytes, coupled to multivariate curve resolution with alternating least squares (MCR-ALS).OD/UV-MCR proved to be robust and was successfully validated in accordance to ICH guidelines, fulfilling acceptance criteria for specificity (r2 of spectral correlation > 0.950), linearity [r > 0.999 (N = 25) in the ranges 1.00–31.1 mg l−1 and 0.51–15.2 mg l−1 for CAR and HCT, respectively] and precision (RSD < 2%). Accuracy was assessed by point-to-point comparison between the dissolution profiles furnished by the proposed method with those provided by HPLC analysis, evidencing the usefulness of this monitoring system.In addition, OD/UV-MCR was successfully employed for the comparative analysis of three lots of commercial formulations of the CAR–HCT pharmaceutical association, belonging to a couple of different brands, employing Moore and Flanner's f2 similarity indicator.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 89, 15 February 2014, Pages 213–220
نویسندگان
, , ,