کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1221490 1494646 2014 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improved liquid–liquid extraction with inter-well volume replacement dilution workflow and its application to quantify BMS-927711 in rat dried blood spots by UHPLC–MS/MS
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Improved liquid–liquid extraction with inter-well volume replacement dilution workflow and its application to quantify BMS-927711 in rat dried blood spots by UHPLC–MS/MS
چکیده انگلیسی


• An inter-well volume replacement workflow was introduced for DBS sample dilution.
• An improved liquid–liquid extraction was used to improve analyte elution from DBS.
• These strategies were applied to quantify BMS-927711, a drug candidate, in rat DBS.
• Excellent assay robustness, precision and accuracy were achieved.
• It has been applied to non-clinical toxicokinetic studies in rats.

An UHPLC–MS/MS method was developed and validated to quantify BMS-927711, a drug candidate to treat migraine, in rat dried blood spots (DBS). The DBS samples were extracted using an improved liquid–liquid extraction (LLE) strategy involving in the sonication of DBS punches in 20% MeOH aqueous solution containing the internal standard, [13C2, D4]-BMS-927711, and then with a 100 mM NH4OAc buffer solution, followed by an automated LLE with EtOAc–hexane (70:30, v/v). The presence of 20% MeOH as an organic modifier in the elution solution significantly improved the analyte elution efficiency and assay performance. A novel inter-well volume replacement dilution workflow was introduced for DBS sample dilution before LLE step. This was a simple two-step process, firstly a small portion of the DBS blank solution was discarded, and then the same volume of a concentrated DBS sample solution was spiked into the leftover blank solution to achieve a desired dilution. Chromatographic separation was achieved on an Acuity UPLC® BEH C18 column (2.1 mm × 50 mm, 1.7μm) and the analyte was detected by selected reaction monitoring (SRM) with positive electrospray ionization on an AB Sciex Triple Quad 5500 mass spectrometer. The standard curve was linear from 5.00 to 5000 ng/mL with assay precision ≤4.9% CV, and assay accuracy within ±3.1%Dev of the nominal values. Accurate sample dilution was achieved by using inter-well volume replacement with a precision of ≤4.2% CV and an accuracy of ±3.3% for dilution QC at 50,000 ng/mL with 100-fold dilution (n = 18). This robust UHPLC–MS/MS assay has been successfully applied to the non-clinical studies in rats. By using inter-well volume replacement workflow, accurate dilution was demonstrated using only one DBS blank sample for a typical dilution of <50-fold, and using only two blank DBS samples for a dilution of up to 625-fold. Moreover, this new workflow makes it easier to automate DBS sample dilution.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 89, 15 February 2014, Pages 240–250
نویسندگان
, , , , , , , , , , ,