Study on warfarin plasma concentration and its correlation with international normalized ratio
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Study on warfarin plasma concentration and its correlation with international normalized ratio
چکیده انگلیسی

A sensitive high-performance liquid chromatographic (HPLC) method was developed for warfarin determination in plasma of patients who undertook cardiac valve replacement and were on anticoagulation with warfarin. The method described proved to be accurate, sensitive, easy to perform, reproducible and specific for plasma warfarin measurement with relative standard deviation (R.S.D.) of <5.27% for inter-day and <6.89% for intra-day. The assay was linear in warfarin concentration ranges of 0.12–3 μg/ml (r = 0.9995) with mean recovery of 94.6%. The mean warfarin plasma concentration of 58 patients with heart valve replacement within 1 month of post operation was 567.6 ± 122.3 ng/ml. The anticoagulant effect of the drug was monitored by international normalized ratio (INR). The correlation of warfarin dosage and concentration with INR was analysed, and the coefficients were 0.21, 0.1 

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 42, Issue 2, 18 September 2006, Pages 218–222