Development and validation of a method for the quantitation of Δ9 tetrahydrocannabinol in human plasma by high performance liquid chromatography after solid-phase extraction
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development and validation of a method for the quantitation of Δ9 tetrahydrocannabinol in human plasma by high performance liquid chromatography after solid-phase extraction
چکیده انگلیسی

A high performance liquid chromatography (HPLC) procedure for the determination of Δ9 tetrahydrocannabinol (THC) in human plasma is described. A two-step solid-phase extraction on CN cartridges was coupled with a reversed phase HPLC system. THC was eluted using a mobile phase composed of methanol, acetonitrile and tetrabutylammonium perchlorate solution (0.005 M, pH 3.2), through a C18 Nucleosil column and detected at a wavelength of 215 nm. Calibration curve was linear over the range 5–100 ng/ml with a lower limit of quantification validated at 5 ng/ml. Extraction recovery using the developed extraction procedure was higher than 85%. This method is presently used for the quantification of THC in plasma samples from regular cannabis smokers.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 41, Issue 3, 7 June 2006, Pages 1011–1016
نویسندگان
, , , , ,