کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1239888 1495726 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water
چکیده انگلیسی

The diffusive gradients in thin films (DGT) technique has shown enormous potential for labile metal monitoring in fresh water due to the preconcentration, time-integrated, matrix interference removal and speciation analytical features. In this work, the coupling of energy dispersive X-ray fluorescence (EDXRF) with paper-based DGT devices was evaluated for the direct determination of Mn, Co, Ni, Cu, Zn and Pb in fresh water. The DGT samplers were assembled with cellulose (Whatman 3 MM chromatography paper) as the diffusion layer and a cellulose phosphate ion exchange membrane (Whatman P 81 paper) as the binding agent. The diffusion coefficients of the analytes on 3 MM chromatography paper were calculated by deploying the DGT samplers in synthetic solutions containing 500 μg L- 1 of Mn, Co, Ni, Cu, Zn and Pb (4 L at pH 5.5 and ionic strength at 0.05 mol L- 1). After retrieval, the DGT units were disassembled and the P 81 papers were dried and analysed by EDXRF directly. The 3 MM chromatographic paper diffusion coefficients of the analytes ranged from 1.67 to 1.87 × 10- 6 cm2 s- 1. The metal retention and phosphate group homogeneities on the P 81 membrane was studied by a spot analysis with a diameter of 1 mm. The proposed approach (DGT-EDXRF coupling) was applied to determine the analytes at five sampling sites (48 h in situ deployment) on the Piracicaba river basin, and the results (labile fraction) were compared with 0.45 μm dissolved fractions determined by synchrotron radiation-excited total reflection X-ray fluorescence (SR-TXRF). The limits of detection of DGT-EDXRF coupling for the analytes (from 7.5 to 26 μg L- 1) were similar to those obtained by the sensitive SR-TXRF technique (3.8 to 9.1 μg L- 1).


► DGT-EDXRF was coupled for Mn, Co, Ni, Cu, Zn and Pb determination in fresh water
► Determination of metal diffusion coefficients in 3 MM paper was performed
► The DGT-EDXRF approach was applied for in situ river sampling
► Limits of detection of DGT-EDXRF were similar to SR-TXRF

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part B: Atomic Spectroscopy - Volumes 71–72, May–June 2012, Pages 70–74
نویسندگان
, , ,