کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1239981 1495693 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Laser-induced breakdown spectroscopy: Extending its application to soil pH measurements
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Laser-induced breakdown spectroscopy: Extending its application to soil pH measurements
چکیده انگلیسی


• Physical, chemical, and biological properties of soil are influenced by pH.
• The pH of mineral soils is normally determined in slurries of water and soil sample by potentiometric measurements.
• The association of LIBS elemental emissions with multivariate strategies of analysis has become LIBS a powerful technique.
• LIBS was unprecedentedly applied for direct pH determination in different kinds of soil sample.
• The clean and fast proposed method encloses the possibility of pH determination in addition of nutrients and contaminants using a single LIBS measurement.

Acid–base equilibria are involved in almost all the processes that occur in soil. The bioavailability of nutrients for plants, for instance, depends on the solubilization of mineral nutrients in the soil solution, which is a pH-dependent process. The determination of pH in soil solutions is usually carried out by potentiometry using a glass membrane electrode, after extracting some of the soil components with water or CaCl2 solution. The present work describes a simple method for determining the pH of soil, using laser-induced breakdown spectroscopy (LIBS). Sixty samples presenting different textural composition and pH (previously determined by potentiometry) were employed. The samples were divided into a calibration set with fifty samples and a validation set with ten samples. LIBS spectra were recorded for each pelleted sample using laser pulse energy of 115 mJ. The intensities of thirty-two emission lines for Al, Ca, H, and O were used to fit a partial least squares (PLS) model. The model was validated by prediction of the pH of the validation set samples, which showed good agreement with the reference values. The prediction mean absolute error was 0.3 pH units and the root mean square error of the prediction was 0.4. These results highlight the potential of LIBS for use in other applications beyond elemental composition determinations. For soil analysis, the proposed method offers the possibility of determining pH, in addition to nutrients and contaminants, using a single LIBS measurement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part B: Atomic Spectroscopy - Volume 110, 1 August 2015, Pages 96–99
نویسندگان
, , , , ,