کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1240753 969140 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigation into the determination of trimethylarsine in natural gas and its partitioning into gas and condensate phases using (cryotrapping)/gas chromatography coupled to inductively coupled plasma mass spectrometry and liquid/solid sorption techniques
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Investigation into the determination of trimethylarsine in natural gas and its partitioning into gas and condensate phases using (cryotrapping)/gas chromatography coupled to inductively coupled plasma mass spectrometry and liquid/solid sorption techniques
چکیده انگلیسی

Speciation of trialkylated arsenic compunds in natural gas, pressurized and stable condensate samples from the same gas well was performed using (Cryotrapping) Gas Chromatography-Inductively Coupled Plasma Mass Spectrometry. The major species in all phases investigated was found to be trimethylarsine with a highest concentration of 17.8 ng/L (As) in the gas phase and 33.2 μg/L (As) in the stable condensate phase. The highest amount of trimethylarsine (121 μg/L (As)) was found in the pressurized condensate, along with trace amounts of non-identified higher alkylated arsines. Volatile arsenic species in natural gas and its related products cause concern with regards to environment, safety, occupational health and gas processing. Therefore, interest lies in a fast and simple field method for the determination of volatile arsenicals. Here, we use simple liquid and solid sorption techniques, namely absorption in silver nitrate solution and adsorption on silver nitrate impregnated silica gel tubes followed by total arsenic determination as a promising tool for field monitoring of volatile arsenicals in natural gas and gas condensates. Preliminary results obtained for the sorption-based methods show that around 70% of the arsenic is determined with these methods in comparison to volatile arsenic determination using GC-ICP-MS. Furthermore, an inter-laboratory- and inter-method comparison was performed using silver nitrate impregnated silica tubes on 14 different gas samples with concentrations varying from below 1 to 1000 μg As/m3 natural gas. The results obtained from the two laboratories differ in a range of 10 to 60%, but agree within the order of magnitude, which is satisfactory for our purposes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Spectrochimica Acta Part B: Atomic Spectroscopy - Volume 62, Issue 9, September 2007, Pages 970–977
نویسندگان
, , , , , ,