کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1241783 1495777 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection
ترجمه فارسی عنوان
یک روش سبز برای اندازه گیری پراکنده گان غدد درون ریز پلاستیک در نوشیدنی ها با استفاده از روش کروماتوگرافی مایع با کمک شیمیایی با استفاده از آرایه دیود همزمان و تشخیص فلورسنت
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A green chromatographic method for plastics-derived endocrine disruptors is developed.
• Six endocrine disruptors of concern are determined in a wide type of beverages.
• Diode array and fluorescence dual detection in a single run offers versatility.
• Outstanding selectivity is attained with MCR-ALS second-order algorithm.
• Chemometrics allows that compounds of different polarity are rapidly quantified.

The aim of this study was to develop a novel analytical method for the determination of bisphenol A, nonylphenol, octylphenol, diethyl phthalate, dibutyl phthalate and diethylhexyl phthalate, compounds known for their endocrine-disruptor properties, based on liquid chromatography with simultaneous diode array and fluorescent detection. Following the principles of green analytical chemistry, solvent consumption and chromatographic run time were minimized. To deal with the resulting incomplete resolution in the chromatograms, a second-order calibration was proposed. Second-order data (elution time-absorbance wavelength and elution time-fluorescence emission wavelength matrices) were obtained and processed by multivariate curve resolution-alternating least-squares (MCR-ALS). Applying MCR-ALS allowed quantification of the analytes even in the presence of partially overlapped chromatographic and spectral bands among these compounds and the potential interferents. The obtained results from the analysis of beer, wine, soda, juice, water and distilled beverage samples were compared with gas chromatography-mass spectrometry (GC-MS). Limits of detection (LODs) in the range 0.04–0.38 ng mL−1 were estimated in real samples after a very simple solid-phase extraction. All the samples were found to contain at least three EDs, in concentrations as high as 334 ng mL−1.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 159, 1 October 2016, Pages 336–343
نویسندگان
, , ,