کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242035 1495803 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of gold nanoparticles modified screen-printed carbon electrode for the analysis of thiram, disulfiram and their derivative in food using ultra-high performance liquid chromatography
ترجمه فارسی عنوان
توسعه نانو ذرات طلا از الکترودهای کربن روی صفحه نمایش چاپ شده برای تجزیه و تحلیل تریام، دیسولفیرام و مشتقات آن در مواد غذایی با استفاده از کروماتوگرافی مایع با کارایی فوق العاده بالا
کلمات کلیدی
دیتیو کربرمات ها، قارچ کش ها، الکترود کربن روی صفحه نمایش، نانوذرات طلا، تعیین همزمان، کروماتوگرافی مایع با کارایی فوق العاده بالا
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• AuNPs modified SPCE is a new detector for determination of DTCs residues in food.
• The method is the effective alternative for rapid, selective and high sensitivity.
• We conclude the newly proposed system is attractive for food routine assay.

For the first time, gold nanoparticles (AuNPs) modified screen-printed carbon electrode (SPCE) was developed as working electrode in ultra-high performance liquid chromatography (UHPLC) coupled with electrochemical detection (UHPLC-ED) for simultaneous determination of thiram, disulfiram, and N,N-diethyl-N’,N’-dimethylthiuram disulfide, their derivative compound. The separation was performed in reversed-phase mode using C18 column, mobile phase consisting of 55:45 (v/v) ratio of 0.05 M phosphate buffer solution (pH 5) and acetonitrile at a flow rate of 1.5 mL min−1. For the detection part, the amperometric detection was chosen with a detection potential of 1.2 V vs. Ag/AgCl. Under the optimal conditions, the good linear relationship was obtained in the range of 0.07–15, 0.07–12, and 0.5–15 µg mL−1 (correlation coefficient more than 0.9900) for thiram, N,N-diethyl-N’,N’-dimethylthiuram disulfide, and disulfiram, respectively. The limits of detection (LODs) of thiram, N,N-diethyl-N’,N’-dimethylthiuram disulfide, and disulfiram were 0.022, 0.023, and 0.165 µg mL−1, respectively. Moreover, this method was successfully applied for the detection of these compounds in real samples (apple, grape and lettuce) with the recoveries ranging from 94.3% to 108.8%. To validate this developed method, a highly quantitative agreement was clearly observed compared to standard UHPLC–UV system. Therefore, the proposed electrode can be effectively used as an alternative electrode in UHPLC-ED for rapid, selective, highly sensitive, and simultaneous determination of thiram, disulfiram, and N,N-diethyl-N’,N’-dimethylthiuram disulfide.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 132, 15 January 2015, Pages 416–423
نویسندگان
, , ,