کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242224 1495785 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Smart detection of microRNAs through fluorescence enhancement on a photonic crystal
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Smart detection of microRNAs through fluorescence enhancement on a photonic crystal
چکیده انگلیسی


• A bio-functional surface for specific microRNA capture was prepared.
• The optimized protocols were adapted to the surface of a photonic crystal.
• MicroRNAs capture and detection on the photonic crystal is demonstrated.
• Significant fluorescence enhancement compared to standard fluorescence microscopy.
• Compact dedicated read-out system with little optical alignment issues.

The detection of low abundant biomarkers, such as circulating microRNAs, demands innovative detection methods with increased resolution, sensitivity and specificity. Here, a biofunctional surface was implemented for the selective capture of microRNAs, which were detected through fluorescence enhancement directly on a photonic crystal. To set up the optimal biofunctional surface, epoxy-coated commercially available microscope slides were spotted with specific anti-microRNA probes. The optimal concentration of probe as well as of passivating agent were selected and employed for titrating the microRNA hybridization. Cross-hybridization of different microRNAs was also tested, resulting negligible. Once optimized, the protocol was adapted to the photonic crystal surface, where fluorescent synthetic miR-16 was hybridized and imaged with a dedicated equipment. The photonic crystal consists of a dielectric multilayer patterned with a grating structure. In this way, it is possible to take advantage from both a resonant excitation of fluorophores and an angularly redirection of the emitted radiation. As a result, a significant fluorescence enhancement due to the resonant structure is collected from the patterned photonic crystal with respect to the outer non-structured surface. The dedicated read-out system is compact and based on a wide-field imaging detection, with little or no optical alignment issues, which makes this approach particularly interesting for further development such as for example in microarray-type bioassays.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 150, 1 April 2016, Pages 699–704
نویسندگان
, , , , , , , ,