کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242411 1495780 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preconcentration and determination of vanadium and molybdenum in milk, vegetables and foodstuffs by ultrasonic-thermostatic-assisted cloud point extraction coupled to flame atomic absorption spectrometry
ترجمه فارسی عنوان
پیش گیری و تعیین وانادیوم و مولیبدن در شیر، سبزیجات و مواد غذایی توسط استخراج نقطه ابرسیونی از طریق ترموستات با استفاده از طیف سنجی جذب اتمی شعله
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A new UTA-CPE was established for the simultaneous extraction of Mo and V prior to detection by FAAS.
• The procedure has been successfully applied into different food samples and SRMs.
• The process is independent of the matrix.
• The method has low detection limits of 0.86 and 1.55 µg L−1 for Mo and V, respectively.

A new ultrasonic-thermostatic-assisted cloud point extraction procedure (UTA-CPE) was developed for preconcentration at the trace levels of vanadium (V) and molybdenum (Mo) in milk, vegetables and foodstuffs prior to determination via flame atomic absorption spectrometry (FAAS). The method is based on the ion-association of stable anionic oxalate complexes of V(V) and Mo(VI) with [9-(diethylamino)benzo[a]phenoxazin-5-ylidene]azanium; sulfate (Nile blue A) at pH 4.5, and then extraction of the formed ion-association complexes into micellar phase of polyoxyethylene(7.5)nonylphenyl ether (PONPE 7.5). The UTA-CPE is greatly simplified and accelerated compared to traditional cloud point extraction (CPE). The analytical parameters optimized are solution pH, the concentrations of complexing reagents (oxalate and Nile blue A), the PONPE 7.5 concentration, electrolyte concentration, sample volume, temperature and ultrasonic power. Under the optimum conditions, the calibration curves for Mo(VI) and V(V) are obtained in the concentration range of 3–340 µg L−1 and 5–250 µg L−1 with high sensitivity enhancement factors (EFs) of 145 and 115, respectively. The limits of detection (LODs) for Mo(VI) and V(V) are 0.86 and 1.55 µg L−1, respectively. The proposed method demonstrated good performances such as relative standard deviations (as RSD %) (≤3.5%) and spiked recoveries (95.7–102.3%). The accuracy of the method was assessed by analysis of two standard reference materials (SRMs) and recoveries of spiked solutions. The method was successfully applied into the determination of trace amounts of Mo(VI) and V(V) in milk, vegetables and foodstuffs with satisfactory results.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 155, 1 August 2016, Pages 38–46
نویسندگان
, , ,