کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1242580 1495782 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of an on-line solid phase extraction method based on new functionalized magnetic nanoparticles. Use in the determination of mercury in biological and sea-water samples
ترجمه فارسی عنوان
توسعه یک روش استخراج فاز جامد بر روی شبکه مبتنی بر نانوذرات مغناطیسی کاربردی جدید. در تعیین جیوه در نمونه های بیولوژیکی و آب دریا استفاده می شود
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• DPTH-MNPs has demonstrated to be promising for routine determination of trace metals.
• The method has good analytical characteristics compared with other similar methods.
• There are few papers describing on line SPME with functionalized MNPs.

A new chelating sorbent which employs magnetic nanoparticles (MNPs) functionalized with 1,5-bis(di-2-pyridil)methylene thiocarbohydrazide (DPTH-MNPs) was synthetized and characterized. The aim of the synthesis of this material was to develop fast and simple methods for analysis of trace amounts of metal ions present in biological and environmental samples combining on-line magnetic solid phase microextraction (MSPME) with atomic spectrometry. The MNPs’ magnetic core allows overcoming the backpressure problems that usually happen in SPME methods with NPs thanks to the possibility of immobilizing the MNPs by applying an external magnetic field. Thus, a flow injection FI-MSPME/cold vapor generation system coupled to an electrothermal atomic absorption spectrometer (CV-ETAAS) method for the determination of trace amounts of Hg in biological and sea-water samples was developed. A magnet based reactor designed to contain DPTH-MNPs was placed in the injection valve of the FI manifold. Several chemical and flow variables were considered as factors in the optimization process using central composite designs. With the optimized procedure, the detection limit obtained was 7.8 ng L−1 with a precision of 1.7% (RSD) (1.0 μg L−1 Hg). The linear range of the method was studied, and two sections of linear calibration were obtained: from determination limit (0.099 µg L−1) to 10 µg L−1, and from 10 µg L−1 to at least 50 µg L−1. A preconcentration factor of 5.4 was calculated. The accuracy of the proposed method was demonstrated by analyzing three certified reference materials and by determining the analyte content in spiked sea-water samples. The determined values were in good agreement with the certified values and the recoveries for the spiked samples were in the range of 97.0–107.0%.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 153, 1 June 2016, Pages 228–239
نویسندگان
, , , , , ,