کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1243760 1495787 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Identification and quantification of seven volatile n-nitrosamines in cosmetics using gas chromatography/chemical ionization–mass spectrometry coupled with head space-solid phase microextraction
ترجمه فارسی عنوان
شناسایی و اندازه گیری هفت نیتروسیمین ناپایدار در لوازم آرایشی با استفاده از کروماتوگرافی گاز / یونیزاسیون شیمیایی، طیف سنجی جرمی و میکروسکاشی فاز سر
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Analytical method was developed for volatile n-nitrosamines in cosmetics.
• The identification was carried out with accurate mass measurements.
• HS-SPME method was optimized for sample treatment.
• Method validation was conducted on linearity, recovery and MDL.

An analytical method was developed for the identification and quantification of seven volatile n-nitrosamines (n-nitrosodimethylamine [NDMA], n-nitrosoethylmethylamine [NMEA], n-nitrosodiethylamine [NDEA], n-nitrosodipropylamine [NDPA], n-nitrosodibutylamine [NDBA], n-nitrosopiperidine [NPIP], and n-nitrosopyrrolidine [NPYR]) in water insoluble cream type cosmetics. It was found that the head space-solid phase microextraction (HS-SPME) was suitable for extraction, clean up, and pre-concentration of n-nitrosamines in the cream type samples so its optimal conditions were investigated. Identification and quantification of n-nitrosamines using single quadrupole gas chromatography/mass spectrometry (GC/MS) in chemical ionization (CI) mode were carried out with accurate mass measurements. Their accurate masses of protonated molecular ions were obtained within 10 mDa of the theoretical masses when sufficiently high signal was acquired from the unique calibration method using mass and isotope accuracy. For the method validation of quantification, spiking experiments were carried out to determine the linearity, recovery, and method detection limit (MDL) using three deuterated internal standards. The average recovery was 79% within 20% relative standard deviation (RSD) at the concentration of 50 ng/g. MDLs ranged from 0.46 ng/g to 36.54 ng/g, which was satisfactory for the directive limit of 50 ng/g proposed by the European Commission (EC). As a result, it was concluded that the method could be provided for the accurate mass screening, confirmation, and quantification of n-nitrosamines when applied to cosmetic inspection.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 148, 1 February 2016, Pages 69–74