کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1247093 | 969798 | 2008 | 7 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Determination of trace glucose and forecast of human diseases by affinity adsorption solid substrate-room temperature phosphorimetry based on triticum vulgaris lectin labeled with dendrimers-porphyrin dual luminescence molecule
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
In this paper, 3.5-generation polyamidoamine dendrimers (3.5G-D)-porphyrin (P) dual luminescence molecule (3.5G-D-P) was developed as a new phosphorescence-labeling reagent. Meanwhile, the room temperature phosphorescence (RTP) characteristics of 3.5G-D-P and its product of labeling triticum vulgaris lectin (WGA) on the surface of polyamide membrane (PAM) were studied. Results showed that in the presence of heavy atom perturber LiAc, 3.5G-D and P of 3.5G-D-P molecule could emit strong and stable RTP on the PAM. And the Tween-80 would spike thoroughly the phosphorescence signal of 3.5G-D and P; moreover, specific affinity absorption (AA) reaction between the products (Tween-80-3.5G-D-P-WGA) of WGA labeled with Tween-80-3.5G-D-P and glucose (G) was carried out. The products of the AA reaction could keep good RTP characteristics of 3.5G-D and P dual luminescence molecule, and the ÎIp was linear correlation to the content of G. According to the facts above, a new method of affinity adsorption solid substrate-room temperature phosphorimetry (AA-SS-RTP) for the determination of trace G was established, basing on WGA labeled with Tween-80-3.5G-D-P dual luminescence molecule. The detection limit of this method was 0.13 fg spotâ1 (1.7 Ã 10â12 mol lâ1, 3.5G-D) and 0.14 fg spotâ1 (2.2 Ã 10â12 mol lâ1, P). Determination of G in human serum using excitation/emission wavelength of either 3.5G-D or P, the result was coincided with enzyme-linked immunosorbent assay (ELISA). Not only the sensitivity and accuracy of this method were higher, but also the flexibility of AA-SS-RTP was obviously improved and the applicability was wider.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Talanta - Volume 74, Issue 4, 15 January 2008, Pages 625-631
Journal: Talanta - Volume 74, Issue 4, 15 January 2008, Pages 625-631
نویسندگان
Jia-Ming Liu, Zhen-Bo Liu, Guo-Hui Zhu, Xue-Lin Li, Xiao-Mei Huang, Fei-Ming Li, Xiu-Mei Shi, Li-Qing Zeng,