Gas tank fill-up in globally minimum time: Theory and application to hydrogen
ترجمه فارسی عنوان
مخزن گاز به حداقل رساندن زمان جهانی پر می شود: نظریه و کاربرد در هیدروژن
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
چکیده انگلیسی


• A minimum time optimal control problem is formulated for gas fill-up process.
• Problem is decomposed into a process simulation and a simple optimal control.
• Process simulation solution is found uniquely, determines feasibility of a fill-up.
• Global solution of simple optimal control is obtained analytically.
• Mass flowrate minimum time strategy is determined to be maximum flowrate.

The process of filling-up high-pressure gas storage vessels consists of a gas source tank, an isenthalpic (Joule–Thomson or J–T) valve, a cooling system, and a gas storage vessel. These units are assumed to be thermally insulated. The fill-up process is formulated as a minimum time optimal control problem. Despite the nonlinear nature of the aforementioned optimal control problem, its global solution is obtained analytically. A novel transformation technique is employed, to decompose the problem into a process simulation problem independent of time, and a simpler minimum time control problem that only depends on the final molar density value and the maximum allowable feed mass flowrate. The feasibility of the fill-up is uniquely determined by the process simulation problem, and upon fill-up feasibility, the minimum time control problem is then globally solved. Two fill-up case studies, involving two different system configurations are analyzed. In Case 1, the fill-up process has a constant molar enthalpy feed, and no cooling system. Case 2 considers a fill-up process with a constant temperature feed, delivered by an efficient cooling system. It was demonstrated that the optimal control strategy to achieve minimum fill-up time is to have the mass flowrate at its maximum allowable value during the entire duration of the fill-up. The presented problem formulation is general and can be applied to the fill-up of other gases, such as compressed natural gas.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Hydrogen Energy - Volume 39, Issue 23, 4 August 2014, Pages 12138–12157
نویسندگان
, ,