کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1278217 1497617 2009 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effects of the geometrical configuration of a ventilation system on leaking hydrogen dispersion and accumulation
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Effects of the geometrical configuration of a ventilation system on leaking hydrogen dispersion and accumulation
چکیده انگلیسی

Hydrogen dispersion and accumulation in a partially open space with natural and forced ventilation are computationally investigated in this paper. After validating the present numerical method and assessing grid width against experimental data of a hallway, the present method is applied to a garage with dimensions of 2.6 m × 2.6 m × 2.6 m and leak flow rates of 0.5–4 standard cubic feet per minute (SCFM). In the simulations, different combinations of roof vents and door vents are considered by changing their sizes and positions. Based on the results, differences in concentration increase, the processes of hydrogen dispersion and accumulation, unsteadiness and vortical structures accompanying ventilation, are shown for natural and forced ventilation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Hydrogen Energy - Volume 34, Issue 24, December 2009, Pages 9869–9878
نویسندگان
,