کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1288 80 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An electrochemical study on self-ordered nanoporous and nanotubular oxide on Ti–35Nb–5Ta–7Zr alloy for biomedical applications
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بیو مهندسی (مهندسی زیستی)
پیش نمایش صفحه اول مقاله
An electrochemical study on self-ordered nanoporous and nanotubular oxide on Ti–35Nb–5Ta–7Zr alloy for biomedical applications
چکیده انگلیسی

Highly ordered nanoporous and nanotubular oxide layers were developed on low-rigidity β Ti–35Nb–5Ta–7Zr alloy by controlled DC anodization in electrolyte containing 1 M H3PO4 and 0.5 wt.% NaF at room temperature. The as-formed and crystallized nanotubes were characterized by electron microscopy, energy-dispersive X-ray spectrometry and X-ray diffraction. The electrochemical passivation behavior of the nanoporous and nanotubular oxide surfaces were investigated in Ringer’s solution at 37 ± 1 °C employing a potentiodynamic polarization technique and impedance spectroscopy. The diameters of the as-formed nanotubes were in the range of 30–80 nm. The nanotubular surface exhibited passivation behavior similar to that of the nanoporous surface. However, the corrosion current density was considerably higher for the nanotubular alloy. The surface after nanotube formation seemed to favor an immediate and effective passivation. Electrochemical impedance spectra were simulated by equivalent circuits and the results were discussed with regard to biomedical applications.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Acta Biomaterialia - Volume 5, Issue 6, July 2009, Pages 2303–2310
نویسندگان
, , ,