کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1427332 | 986859 | 2007 | 8 صفحه PDF | دانلود رایگان |
The colloidal phenomenon of soft particles is becoming an important field of research due to the growing interest in using polymeric system in drug delivery. Previous studies have focused on techniques that require intermediate process step such as dialysis or centrifugation, which introduces additional errors in obtaining the diffusion kinetic data. In this study, a drug selective electrode was used to directly measure the concentration of procaine hydrochloride (PrHy) released from methacrylic acid–ethyl acrylate (MAA–EA) microgel, thereby eliminating the intermediate process step. PrHy selective membrane constructed using a modified poly (vinyl chloride) (PVC) membrane and poly (ethylene-co-vinyl acetate-co-carbon monoxide) as plasticizer exhibited excellent reproducibility and stability. The response was reproducible at pH of between 3 to 8.5 and the selectivity coefficients against various organic and inorganic cations were evaluated. Drug release was conducted using the drug electrode under different pHs and the release rate increased with pH. The release behavior of the system under different pH exhibited obvious gradient release characteristics.
Journal: Journal of Controlled Release - Volume 118, Issue 1, 12 March 2007, Pages 87–94