کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1761113 | 1019634 | 2009 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Flow-Mediated Dilation and Intima-Media Thickness of the Brachial and Axillary Arteries in Individuals With and Without Inducible Axillary Artery Compression
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
آکوستیک و فرا صوت
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
The presence of axillary artery aneurysm and/or thrombus in overhead throwing athletes has been linked, theoretically, with the finding of compression by the humeral head induced by a diagnostic arm maneuver. However, whether this intermittent compression is incidental or of pathological significance has yet to be determined. Flow-mediated vasodilation (FMD), intima-media thickness (IMT) and maximum vasodilatory capacity were measured locally (3rd portion of the axillary artery) and downstream (brachial artery) in individuals previously tested for inducible axillary artery compression (compressor group [COMP]: n = 8, mean (SD) age: 23 (4) y; “noncompressor” control group [NONCOMP]: n = 8, 26 (4) y). A high-resolution ultrasound machine recorded arterial diameter and blood flow velocity. A rapid inflation/deflation pneumatic cuff placed distal to the site of measurement induced reactive hyperemia. Custom-designed wall tracking software with synchronized Doppler waveform analysis detected changes in arterial diameter, blood flow velocity and shear rate from baseline to 3 min after cuff deflation. Glyceryl trinitrate and/or ischemic hand grip exercises were administered to induce maximum vasodilation. No significant differences in FMD, IMT or maximum vasodilator capacity were observed between groups at the axillary artery. However, the downstream brachial FMD response was significantly diminished in the COMP group (6.38 [3.28]%) compared with the NONCOMP group (10.38 [2.74]%; p = 0.006) despite a comparable shear rate between groups (COMP: 81.92 (44.55) sâ1; NONCOMP: 83.18 (40.02) sâ1; p = 0.961). Pooled data revealed a significant negative relationship (r = â0.52, p = 0.038) between the FMD response and degree of arterial compression. These results suggest a chronic change in downstream vascular function in individuals demonstrating clinically significant inducible axillary artery compression. (E-mail: c.stapleton@2005.ljmu.ac.uk)
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 35, Issue 9, September 2009, Pages 1443-1451
Journal: Ultrasound in Medicine & Biology - Volume 35, Issue 9, September 2009, Pages 1443-1451
نویسندگان
C.H. Stapleton, D.J. Green, N.T. Cable, K.P. George,